Page 15 - ABB_Welcome-Example-systems
P. 15

M2303            1. Station
Guard unit 4.3"     The jumper switch is used to set the address of the primary
                    outdoor unit.
M2300
Central unit     2. X1
                    The jumper switch is used to set the address of the guard
                    unit.

                 3. The master/slave function
                    Only one guard unit in each building must be set to the
                    Master state (the jumper switch set to "M/S on").

                 4. Terminal resistor RC ON/OFF
                    For video or video/audio installations, "RC" must be "ON"
                    in the last unit of each line.

                 5. a b = Bus connectors
                                 = Doorbell connection

                     DC GND = Auxiliary power source connection
                 6. USB connection

                    (QT EQPPGEVKPI VQ C EQORWVGT  NQCF TGCF C ƂNG

                 1. Bus
                 2. Selection of operating mode:

                    One on = the master device alarms
                    All on = master and slave devices alarm
                 3. Status indicator LED

                 Ready to operate Bus activity Fault
                 4. Mains voltage

                                       Example systems | The ABB-Welcome door entry system 15
   10   11   12   13   14   15   16   17   18   19   20